SMPTE LTC Generator (BETA)

The SMPTE LTC Generator component generates a Linear Timecode (LTC) audio signal, per the SMPTE 12M specification.

A start time can be entered into the Hours, Minutes, Seconds and Frames fields. Drop Frame mode can be enabled and the OTWP button can be used to Output Timecode While Paused. The generator stops when the time reaches 23:59:59:29. When stopped, the time fields return to the most recently entered start time.

You can connect the Control Pins of the generator to a Control Script component with an appropriate Lua script to control the generator.

You can connect the generator output to one or more local or networked Q-SYS SMPTE LTC Readers or analog and/or digital output(s).

Controls

Control

Function

Default/Range

Hours

Counts the number of elapsed hours and allows for manually entering the hours.

0 - 23

Minutes

Counts the number of elapsed minutes and allows for manually entering the minutes.

0 - 29

Seconds

Counts the number of elapsed seconds and allows for manually entering the seconds.

0 - 59

Frames

(fps)

Counts the number of elapsed Frames and allows for manually entering the frames.

0 - 29

Drop Frame

The Drop Frame toggle button enables "drop-frame" mode in which frames are periodically dropped to stay in sync with wall clock time.

Off/On

Start

Starts the timecode count from the numbers entered, or from zero if nothing has been entered.

Off/On

Stop

Stops the timecode count. After stopping the count, if the Start button in pressed, the timecode count starts at the numbers originally entered or zero if nothing was entered.

On/Off

Pause

Pauses the timecode count. When restarted the count resumes at the time it was stopped.

Off/On

OTWP

The Output Timecode When Paused (OTWP) toggle button causes the timecode, at which the Writer was stopped, to be repeatedly output when the counter is paused.

Off/On

Properties

Property

Function

Choices

Frame Rate

(fps)

Sets the number of frames per second.

24

25

30 Pull-Down

30

Control Pins

Pin Name

Value

String

Position

Pins Available

Drop Frame

0

1

disabled

enabled

0

1.00

Output

Frames In 1

0 -29

0 - 29

0.00 to 1.00 2

Input/Output

Frames Out 1

0 - 29

0 - 29

0.00 to 1.00 2

Output

Hours In 1

0 - 23

0 - 23

0.00 to 1.00 2

Input/Output

Hours Out 1

0 - 23

0 - 23

0.00 to 1.00 2

Output

Minutes In 1

0 - 59

0 - 59

0.00 to 1.00

(0.017 increments)

Input/Output

Minutes Out 1

0 - 59

0 - 59

0.00 to 1.00

(0.017 increments)

Output

Output Timecode When Paused

0

1

disabled

enabled

0

1.00

Input/Output

Pause

trigger

Input/Output

Paused

0

1

false

true

0

1.00

Output

Seconds In 1

0 - 59

0 - 59

0.00 to 1.00

(0.017 increments)

Input/Output

Seconds Out 1

0 - 59

0 - 59

0.00 to 1.00

(0.017 increments)

Output

Start

trigger

Input/Output

Started

0

1

false

true

0

1.00

Output

Stop

trigger

Input/Output

Stopped

0

1

false

true

0

1.00

Output

1. Frames, Hours, Minutes, and Seconds each have an "In" control pin for setting the time, and each have "Out" control pins for reading the output of the counter.
2. The increments in the position control depend on the number of frames per second.

 

© 2009 - 2016 QSC, LLC. All rights reserved. QSC and the QSC logo are trademarks of QSC, LLC in the U.S. Patent and Trademark office and other countries. All other trademarks are the property of their respective owners.